Wireless inductive sensor
RF IS M12 FL
Metal enclosure
M12 x 1 thread
Flexible (FL) installation with autocalibration
To be connected to RF 96 BU or RF I/O BU universal transmitter
With M8 plug-in connector, 4-pole, A-coded
2 mounting nuts are included in delivery.
Technical data
General technical data
Applied standards
2006/42/EG, 2014/35/EU, 2014/30/EU, 2011/65/EU, EN IEC 60947-5-2
Enclosure
brass, nickeled
Front surface
PVC
Degree of protection
IP67 (IEC/EN 60529)
Ambient temperature
–25 °C … +75 °C
Storage and shipping temperature
–25 °C … +75 °C
Humidity
95 % non condensing
Mounting
threads and nuts: M12
Connection
M8 plug, 4-pole, A-coded
Cable length
0.5 m
Rated operating voltage Ue
3.0 … 3.6 V
Rated operating current Ie
on average max. 25 µA (typ. @Vcc = 3.3 V)
Interfaces
M8 plug, 4-pole, A-coded, 1 switching output, 1 calibration input
Switching distances
Flush installation *:
sn 6 mm, sr 5.4 … 6.6 mm, sa 4.86 mm, su 4.86 … 7.26 mm 
* The values depend on the installation material and installation conditions.
Non-flush installation:
sn 4.2 mm - aluminium 
sn 4.0 mm - steel
Measurement frequency
10 Hz (The maximum frequency at which changes in the switching status can be transmitted depends on the radio system.)
Note
The sensor may only be used in combination with RF 96 BU or RF I/O BU




























                            
                    
                                                    
                                                    