Emergency pull-wire switch
ZS 92 S KST -40°C ... +70°C IP66/67 Extreme
Temperature resistant from -40 °C to +70 °C
High degree of protection IP66 / IP67
Thermoset enclosure
Wire length up to 2 x 100 m
Release by lever
F1 = blue reset lever on front (left)
B1 = blue reset lever on back (up)
Rear and base mounting possible
Wire pull and breakage detection
Loading...
Found 4 results
Product
Standard Version
Product
ZS 92 S 02 VD Si-Bus F1 KST -40°C … +70°C IP66/67 Extreme
Article no. on request
Product
Product
Standard Version
Loaded 4 from 4 results
Technical data
General technical data
- Applied standards
- EN 60947-5-1, EN 60947-5-5, EN ISO 13850, EN ISO 13849-1, EN 620-5.7.2.9, AS 1755-2000-2.7.9.1, AS/NZS 4024.3610:2015-2.10.6.2
- Enclosure
- thermoset, grey, similar to RAL 7035
- Cover
- thermoset, enamel finish, yellow, similar to RAL 1012
- Actuating lever
- thermoset, signal red, similar to RAL 3001
- Reset lever
- thermoset, sky blue, similar to RAL 5015
- Screws
- stainless steel
- Tightening torque
- cover screws: max. 2.5 Nm
- Degree of protection
- IP66/IP67 (IEC/EN 60529)
- B10d (10 % load)
- 100 000
- TM
- max. 20 years
- Switching elements
- 2 NC/2 NO or 3 NC/1 NO contact, type Zb;
Si-Bus: 2 NC contacts, type Zb
- Switching system
- snap action, positive break NC contacts A
- Connection
- screw connection terminals; with Si-Bus: screw connection terminals, basic strip to connect Dupline Safe input module with connector (see accessories)
- Cable cross-section
- 0.34 ... 2.5 mm² (incl. conductor ferrules)
- Cable entry
- 2 x M25 x 1.5
- Rated impulse withstand voltage Uimp
- 4 kV
- Rated insulation voltage Ui
- 500 V; with Si-Bus: 250 V
- Conventional thermal current Ithe
- 10 A
- Utilisation category
- AC-15; DC-13
- Rated operating current/voltage Ie/Ue
- AC-15: 24 V-10 A/120 V-6 A/400 V-4 A
DC-13: 24 V-6A/125 V-0.55 A/250 V-0.4 A
Minimum electrical load: 5 V/10 mA
Si-Bus: 4 A/250 VAC
- Conditional short-circuit current
- 1000 A
- Short-circuit protection
- 10 A gG/gL fuse
- Safety class
- II
- Mechanical life
- > 50 000 operations
- Max. wire length
- 2 x 100 m
- Ambient temperature
- –40 °C … +70 °C
- Note
- At 3 m distance intermediate wire supports are required. Two compensation springs type ZS 92 S must be installed, see accessories.
- Degree of pollution
- 3
- Actuating force
- actuating lever approx. 30 N; reset lever approx. 40 N
- Indicator lamp
- as option
- Pressure equalization element
- as option
- Approvals
- d
Downloads
Variants / Options
The following variants / options are available on request:
Version with Si-Bus
Pressure equalization element