Wireless inductive sensor
RF IS M18 FL
Metal enclosure
M18 x 1 thread
Flexible (FL) installation with autocalibration
To be connected to RF 96 BU or RF I/O BU universal transmitter
With M8 plug-in connector, 4-pole, A-coded, straight or angled
Notes
2 mounting nuts are included in delivery.
Loading...
Found 2 results
Product
new
Product
new
Loaded 2 from 2 results
Technical data
General technical data
- Applied standards
- 2006/42/EG, 2014/35/EU, 2014/30/EU, 2011/65/EU, EN IEC 60947-5-2
- Enclosure
- brass, nickeled
- Front surface
- PVC
- Degree of protection
- IP67 (IEC/EN 60529)
- Ambient temperature
- –25 °C … +75 °C
- Storage and shipping temperature
- –25 °C … +75 °C
- Humidity
- 95 % non condensing
- Mounting
- threads and nuts: M18
- Connection
- plug-in connector M8 x 1, 4-pole, A-coded
- Cable length
- 0.5 m
- Rated operating voltage Ue
- 3.0 … 3.6 V
- Rated operating current Ie
- on average max. 25 µA (typ. @Vcc = 3.3 V)
- Interfaces
- M8 plug, 4-pole, A-coded, 1 switching output, 1 calibration input
- Switching distances
- Non-flush installation:
sn 10 mm, sr 9 … 11 mm, sa 8.1 mm, su 8.1 … 12.1 mm
Flush installation *:
sn 6.6 mm - aluminium
sn 6.3 mm - steel
* The values depend on the installation material and installation conditions.
- Measurement frequency
- 10 Hz (The maximum frequency at which changes in the switching status can be transmitted depends on the radio system.)
- Note
- The sensor may only be used in combination with RF 96 BU or RF I/O BU
Downloads