Ex solenoid interlock

Ex AZM 415


  • Ex zone 1 and 21

  • Special version up to +90 °C ambient temperature for dust Ex zone 21 available (HU)

  • Spring-to-lock or power-to-lock principle

  • Problem-free opening of stressed doors by means of bell-crank system

  • High locking force 3500 N

  • Ball catch

  • Wiring compartment

  • Attention: Please state required international approvals with your order!

Notes
  • 1 additional cable gland M20x1.5 is included in delivery.

  • The actuator is not included in the delivery of the switches.

Technical data

Applied standards
EN 60947-5-1, EN ISO 14119, EN IEC 60079-0, EN 60079-1, EN IEC 60079-7, EN 60079-18, EN 60079-31, EN ISO 13849-1
Enclosure
aluminium die-cast, enamel finish
Cover
aluminium, enamel finish
Actuator
metal zinc
Switch type
type 2
Coding level
low coding
Tightening torque
cover screws: 0.5 … 0.6 Nm
switch inserts M3 screw connection terminals: min. 0.6 Nm
Degree of protection
IP67 (IEC/EN 60529); Ex AZM 415-TE, TEI, -FE: IP64 (IEC/EN 60529)
B10d (10 % load)
2 million
TM
max. 20 years
Switch insert
2 x Ex 95
Contact material
silver
Switching system
slow action, positive break NC contacts A
Switching elements
1 NC/1 NO contact + 1 NC/1 NO contact or 2 NC + 1 NC/1 NO contact
Connection
screw connection terminals
Cable cross-section
min. 0.2 mm² (AWG 24), max. 1.5 mm² (AWG 16)
Cable entry
2 x M20 x 1.5; use only Ex approved and certified cable glands with min. degree of protection IP67
Clamping range
7 … 12 mm
Rated impulse withstand voltage Uimp
4 kV
Rated insulation voltage Ui
250 V
Conventional thermal current Ithe
6 A
Utilisation category
AC-15; DC-13
Rated operating current/voltage Ie/Ue
enabling/signalling contacts: 6 A/250 VAC; 0.25 A/230 VDC;
direct-current solenoid: 0.08 A / 24 VDC ±10 %
Short-circuit protection
6 A gG fuse;
direct-current solenoid: 2 A (slow blow)
Power consumption
max. 12 W (250 ms)
Ambient temperature
T6: –20 °C … +40 °C;
T5: –20 °C … +55 °C
Type HU:–20 °C … +90 °C
Operation cycles
max. 1200/h
Drop-out delay
< 50 ms
Mechanical life
> 1 million operations
Locking force Fmax
3500 N
Locking force of integrated ball catch
50 - 200 N, adjustable
Impact energy
max. 7 J
Ex marking
L II 2G Ex demb IIC T6/T5 Gb,
LII 2D Ex tb IIIC T80°C/T95°C Db IP67/64
IECEx Ex demb IIC T6/T5 Gb,
Ex tb IIIC T80°C/T95°C Db IP67/64

Type HU:
L II 2D Ex tD A21 IP67 T130 °C,
IECEx Ex tb IIIC T130 °C Db IP67

Type FE-HU:
L II 2D Ex tD A21 IP64 T130 °C,
IECEx Ex tb IIIC T130 °C Db IP64
Approvals
DMT 02 ATEX E 255 X
IECEx BVS 07.0018X
f d a
Type HU:
BVS 08 ATEX E 155 X
IECEx BVS 12.0013X

Downloads

Loading...
Choose the type of download
Mounting and wiring instructions – Ex AZM 415 / Ex AZP 415

German, English, French, Italian, Portuguese

PDF 2 MB 13.11.2025
Mounting and wiring instructions – Ex AZM 415 JPEx (ja)

Japanese

PDF 792 KB 13.11.2025
Mounting and wiring instructions – Ex AZM 415 HU

German, English, French, Italian, Portuguese

PDF 884 KB 13.11.2025
Please go to the relevant product pages for additional downloads.
Loading...

Other interesting products

Special version only for dust Ex zone 22

Ex Safety