Product features

ExSafety
  • Ex zone 21

  • Heat-resistant up to +90 °C

  • Power-to-lock principle

  • Problem-free opening of stressed doors by means of bell-crank system

  • High locking force 3500 N

  • Ball catch

  • Wiring compartment

Notes

  • 1 additional cable gland M20x1.5 is included in delivery.

  • The actuator is not included in the delivery of the switches.

Technical data

Applied standards
EN 60947-5-1, EN ISO 14119, EN IEC 60079-0, EN 60079-31, EN ISO 13849-1
Enclosure
aluminium die-cast, enamel finish
Cover
aluminium, enamel finish
Switch type
type 2
Coding level
low coding
Tightening torque
cover screws: 0.5 … 0.6 Nm
switch inserts M3 screw connection terminals: min. 0.6 Nm
Degree of protection
IP67 (IEC/EN 60529)
B10d (10 % load)
2 million
TM
max. 20 years
Switch insert
2 x Ex 95
Contact material
silver
Switching system
slow action, positive break NC contacts A
Switching elements
1 NC/1 NO contact + 1 NC/1 NO contact
Connection
screw connection terminals
Cable cross-section
min. 0.2 mm² (AWG 24), max. 1.5 mm² (AWG 16)
Cable entry
2 x M20 x 1.5; use only Ex approved and certified cable glands with min. degree of protection IP67 and admissible ambient temperature range of -20 °C … +95 °C
Clamping range
6 … 12 mm
Rated impulse withstand voltage Uimp
4 kV
Rated insulation voltage Ui
250 V
Conventional thermal current Ithe
4 A
Utilisation category
AC-15; DC-13
Rated operating current/voltage Ie/Ue
enabling/signalling contacts: 4 A/250 VAC; 0.25 A/230 VDC;
direct-current solenoid: 0.08 A / 24 VDC ±10 %
Short-circuit protection
4 A gG/gN fuse;
direct-current solenoid: 2 A (slow blow)
Power consumption
max. 12 W (250 ms)
Ambient temperature
–20 °C … +90 °C
Operation cycles
max. 1200/h
Drop-out delay
< 50 ms
Mechanical life
> 1 million operations
Locking force Fmax
3500 N
Locking force of integrated ball catch
50 - 200 N, adjustable
Impact energy
max. 7 J
Ex marking
L II 2D Ex tb IIIC T130°C Db IP67,
IECEx Ex tb IIIC T130 °C Db IP67
Approvals
BVS 08 ATEX E 155 X
IECEx BVS 12.0013X
Weight
1000 g

Dimensional drawing

Further drawings

Contact diagram

A positive break
P actuated
Q not actuated
Æ monitoring of the guard-lock to EN ISO 14119

Downloads

Loading...
Choose the type of download
Mounting and wiring instructions – Ex AZM 415 HU

German, English, French, Italian, Portuguese

PDF884 KB 13.11.2025
Loading...

Other interesting products

Special version only for dust Ex zone 22

ExSafety

Ex solenoid interlock

Ex AZM 415 1Ö1S/1Ö1S A-HU +90 °C -2D

Article no.: 1188480Old article no.: 94353906

contact us