Ex solenoid interlock
Ex AZM 415
Ex zone 1 and 21
Special version up to +90 °C ambient temperature for
dust Ex zone 21 available (HU)Spring-to-lock or power-to-lock principle
Problem-free opening of stressed doors by means of bell-crank system
High locking force 3500 N
Ball catch
Wiring compartment
Attention: Please state required international approvals with your order!
Notes
1 additional cable gland M20x1.5 is included in delivery.
The actuator is not included in the delivery of the switches.
Loading...
Found 18 results
Product
Standard Version
Product
Standard Version
Product
Standard Version
Product
Product
Product
Product
Product
Product
Product
Product
Product
Loaded 12 from 18 results
more products
Technical data
General technical data
- Applied standards
- EN 60947-5-1, EN ISO 14119, EN IEC 60079-0, EN 60079-1, EN IEC 60079-7, EN 60079-18, EN 60079-31, EN ISO 13849-1
- Enclosure
- aluminium die-cast, enamel finish
- Cover
- aluminium, enamel finish
- Actuator
- metal zinc
- Switch type
- type 2
- Coding level
- low coding
- Tightening torque
- cover screws: 0.5 … 0.6 Nm
switch inserts M3 screw connection terminals: min. 0.6 Nm
- Degree of protection
- IP67 (IEC/EN 60529); Ex AZM 415-TE, TEI, -FE: IP64 (IEC/EN 60529)
- B10d (10 % load)
- 2 million
- TM
- max. 20 years
- Switch insert
- 2 x Ex 95
- Contact material
- silver
- Switching system
- slow action, positive break NC contacts A
- Switching elements
- 1 NC/1 NO contact + 1 NC/1 NO contact or 2 NC + 1 NC/1 NO contact
- Connection
- screw connection terminals
- Cable cross-section
- min. 0.2 mm² (AWG 24), max. 1.5 mm² (AWG 16)
- Cable entry
- 2 x M20 x 1.5; use only Ex approved and certified cable glands with min. degree of protection IP67
- Clamping range
- 7 … 12 mm
- Rated impulse withstand voltage Uimp
- 4 kV
- Rated insulation voltage Ui
- 250 V
- Conventional thermal current Ithe
- 6 A
- Utilisation category
- AC-15; DC-13
- Rated operating current/voltage Ie/Ue
- enabling/signalling contacts: 6 A/250 VAC; 0.25 A/230 VDC;
direct-current solenoid: 0.08 A / 24 VDC ±10 %
- Short-circuit protection
- 6 A gG fuse;
direct-current solenoid: 2 A (slow blow)
- Power consumption
- max. 12 W (250 ms)
- Ambient temperature
- T6: –20 °C … +40 °C;
T5: –20 °C … +55 °C
Type HU:–20 °C … +90 °C
- Operation cycles
- max. 1200/h
- Drop-out delay
- < 50 ms
- Mechanical life
- > 1 million operations
- Locking force Fmax
- 3500 N
- Locking force of integrated ball catch
- 50 - 200 N, adjustable
- Impact energy
- max. 7 J
- Ex marking
- L II 2G Ex demb IIC T6/T5 Gb,
LII 2D Ex tb IIIC T80°C/T95°C Db IP67/64
IECEx Ex demb IIC T6/T5 Gb,
Ex tb IIIC T80°C/T95°C Db IP67/64
Type HU:
L II 2D Ex tD A21 IP67 T130 °C,
IECEx Ex tb IIIC T130 °C Db IP67
Type FE-HU:
L II 2D Ex tD A21 IP64 T130 °C,
IECEx Ex tb IIIC T130 °C Db IP64
- Approvals
- DMT 02 ATEX E 255 X
IECEx BVS 07.0018X
f d a
Type HU:
BVS 08 ATEX E 155 X
IECEx BVS 12.0013X
Downloads
Loading...