Ex position switch
Ex 14 / ExM 14
Ex zone 1 and 21
Thermoplastic enclosure, double insulated X
Mounting details to EN 50047
Suitable for in-line mounting
With pre-wired cable
Slow or snap action
Attention: Please state required international approvals with your order!
Technical data
General technical data
Applied standards
EN 60947-5-1, EN IEC 60079-0, EN 60079-1, EN 60079-31, EN ISO 13849-1, EN ISO 14119
Enclosure
thermoplastic, glass-fibre reinforced, shockproof, self-extinguishing UL 94 V-0
Switch type
type 1
Coding level
no coding
Degree of protection
IP65 (IEC/EN 60529)
B10d (10 % load)
2 million
TM
max. 20 years
Contact material
silver
Switching system
Ex 14: slow action, positive break NC contacts A; positive break depends on the actuator used
ExM 14: snap action
Switching elements
Ex 14: 1 NC/1 NO contact or 2 NC contacts, type Zb
ExM 14: change-over contact with single break type C or 1 NC/1 NO contact, type Za
Connection
pre-wired cable H05VV-F
Cable cross-section
3 or 4 x 0.75 mm² (incl. conductor ferrules)
Rated impulse withstand voltage Uimp
4 kV
Rated insulation voltage Ui
250 V
Conventional thermal current Ithe
Ex 14: T6: 6 A; T5: 3 A
ExM 14: 5 A
Rated operating current/voltage Ie/Ue
Ex 14: 6 A/250 VAC, 0.25 A/230 VDC;
ExM 14: 5 A/250 VAC, 0.16 A/230 VDC;
ExM 14 1Ö/1S: 5 A/250 VAC, 0.25 A/230 VDC
Utilisation category
Ex 14, ExM 14: AC-15; DC-13
ExM 14 1Ö/1S: AC-1; DC-1
Short-circuit protection
Ex 14: 6 A gG/gN fuse;
ExM 14: 5 A gG/gN fuse
Ambient temperature
Ex 14: T6: –20 °C … +65 °C, T5: –20 °C … +75 °C, +90 °C with max. 3 A
ExM 14: –20 °C … +60 °C
(down to –40 °C available on request)
Mechanical life
> 1 million operations
Operation cycles
max. 1800/h
Repeat accuracy of switching points
± 0.1 mm
Contact opening
max. 2 x 4 mm
Ex marking
Ex 14:
L II 2G Ex db IIC T6/T5 Gb,
L II 2D Ex tb IIIC T80 °C/T95 °C Db
ExM 14:
L II 2G Ex d IIC T6 Gb,
L II 2D Ex tb IIIC T80 °C Db IP65
ExM 14 1Ö/1S:
L II 2G Ex db IIC T6 Gb,
L II 2D Ex tb IIIC T80 °C Db
Approvals
Ex 14:
PTB 03 ATEX 1070 X
IECEx PTB 06.0098X
f a d
ExM 14:
PTB 03 ATEX 1069 X
ExM 14 1Ö/1S:
PTB 00 ATEX 1006 X
IECEx PTB 13.0019X
Downloads
Variants / Options
The following variants / options are available on request:
Cable entry on side
Gold-plated contacts
Contact overlapping (only slow action)
Latching element (On-/Off principle)
Cold-resistant version down to -40 °C
Special version only for dust Ex zone 22