Product features
Thermoplastic enclosure
Design to EN 50047
Horizontally slotted mounting holes
Double insulated X
Cover fixed without screws
Actuator: Rocking lever D
Lever angle adjustable in 10° steps
Wear-resistant plastic roller
Actuator can be repositioned by 4 x 90°
With plug-in connector M12 x 1, 4-pole, A-coded
Technical data
General technical data
Applied standards
EN 60947-5-1, EN ISO 13849-1, EN ISO 14119
Enclosure
thermoplastic, glass-fibre reinforced, shockproof, self-extinguishing UL 94 V-0, weathering resistant, UV stabilised
Switch type
type 1
Coding level
no coding
Degree of protection
IP66/IP67 (IEC/EN 60529), only with plugged cable
B10d (10 % load)
2 million
TM
max. 20 years
Switching system
snap action, positive break NC contacts A
Switching elements
1 NC/1 NO contact, type Zb
Connection
plug-in connector M12 x 1, 4-pole, A-coded
Rated impulse withstand voltage Uimp
0.8 kV
Rated insulation voltage Ui
50 V
Conventional thermal current Ithe
4 A
Utilisation category
AC-15; DC-13
Rated operating current/voltage Ie/Ue
4 A/50 VAC
Short-circuit protection
4 A gG/gL fuse
Operation cycles
max. 1800/h
Mechanical life
> 1 million operations
Ambient temperature
–30 °C … +70 °C
Approvals
d]
Chemical resistance
Enclosure material resistant to:
oil and petrol, alcohol, animal fats and oils, vegetable fats and oils, silicone oils, surfactants, detergents, water vapour, salt water, organic acids (citric acid, benzoic acid)
Enclosure material not resistant to:
mineral acids (concentrated hydrochloric acid, battery acid, sulphuric acid, nitric acid)
Downloads
Variants / Options
The following variants / options are available on request:
Mechanical latching