Pull-wire switch

ES 97 Z


  • Thermoplastic enclosure

  • Wall mounting

  • Slow action

  • Pull-wire function

  • Mounting details to EN 50047

  • Cover fixed without screws

Technical data

Applied standards
EN 60947-5-1
Enclosure
thermoplastic, glass-fibre reinforced, shockproof, self-extinguishing UL 94 V-0, weathering resistant, UV stabilised
Degree of protection
IP66/IP67 (IEC/EN 60529)
Switching system
slow action
Switching elements
1 NC/1 NO contact, type Zb
Connection
screw connection terminals
Cable cross-section
0.34 ... 2.5 mm² (incl. conductor ferrules)
Cable entry
1 x M20 x 1.5 (M16 x 1.5 on request) (for cable glands only)
Rated impulse withstand voltage Uimp
6 kV
Rated insulation voltage Ui
500 V
Conventional thermal current Ithe
10 A
Utilisation category
AC-15; DC-13
Rated operating current/voltage Ie/Ue
AC: 24 V-10 A/120 V-6 A/400 V-4 A
DC: 24 V-6A/125 V-0.55 A/250 V-0.4 A
Minimum electrical load: 5 V/10 mA
Short-circuit protection
10 A gG/gL fuse
Safety class
II
Conditional short-circuit current
1000 A
Operation cycles
max. 1800/h
Mechanical life
1 million operations
Ambient temperature
–30 °C … +70 °C
Actuating force
approx. 25 N

Enclosure material resistant to:
oil and petrol, alcohol, animal fats and oils, vegetable fats and oils, silicone oils, surfactants, detergents, water vapour, salt water, organic acids (citric acid, benzoic acid)

Enclosure material not resistant to:
mineral acids (concentrated hydrochloric acid, battery acid, sulphuric acid, nitric acid)

Downloads

Loading...
Choose the type of download
Mounting and wiring instructions – ES 97 Z

German, English, French, Italian, Portuguese

PDF 3 MB 24.03.2026
Please go to the relevant product pages for additional downloads.