Ex solenoid interlock
Ex STM 295
Ex zone 1 and 21
Thermoplastic enclosure
Wiring compartment
Spring-to-lock or power-to-lock principle
Locking force 1000 N
Attention: Please state required international approvals with your order!
Notes
1 Ex"e" cable gland M20x1.5 included in delivery.
The actuator is not included in the delivery of the switches.
Loading...
Found 15 results
Product
Standard Version
Product
Standard Version
Product
Product
Standard Version
Product
Product
Standard Version
Product
Standard Version
Product
Product
Product
Product
Standard Version
Product
Loaded 12 from 15 results
more products
Technical data
General technical data
- Applied standards
- EN 60947-5-1, EN ISO 14119, EN IEC 60079-0, EN 60079-1, EN IEC 60079-7, EN 60079-18, EN 60079-31, EN ISO 13849-1
- Enclosure
- thermoplastic, glass-fibre reinforced, shockproof, self-extinguishing UL 94 V-0
- Actuator
- stainless steel 1.4301
- Switch type
- type 2
- Coding level
- low coding
- Tightening torque
- cover screws: 0.5 … 0.6 Nm
enclosure mounting screws: 1 … 1.3 Nm
switch inserts M3 screw connection terminals: min. 0.6 Nm
solenoid M3.5 screw connection terminals: min. 0.8 Nm
- Degree of protection
- IP64 (IEC/EN 60529)
- B10d (10 % load)
- 1 million
- TM
- max. 20 years
- Contact material
- silver
- Switching system
- slow action, positive break NC contacts A
- Switching elements
- 1 NC/1 NO contact + 1 NC/1 NO contact or 2 NC + 1 NC/1 NO contact
- Connection
- screw connection terminals
- Cable cross-section
- solenoid: 0.2 … 1.5 mm2 (AWG 24 … 16)
switch inserts: 0.75 … 1.5 mm2 (AWG 18 … 16)
- Cable entry
- 2 x M20 x 1.5; use only Ex approved and certified cable glands with min. degree of protection IP64 and admissible ambient temperature range of -20 °C … +95 °C
- Clamping range
- 7 … 12 mm
- Rated insulation voltage Ui
- 250 V
- Rated impulse withstand voltage Uimp
- 4 kV
- Utilisation category
- AC-15; DC-13
- Rated operating current/voltage Ie/Ue
- enabling/signalling contacts:
2 contacts: 3 A/250 VAC; 0.25 A/230 VDC
3 contacts: 1.5 A/250 VAC; 0,2 A/230 VDC;
direct-current solenoid: 0.08 A / 24 VDC +10 %/–15 %
- Short-circuit protection
- 3 A / 1.5 A gG fuse;
direct-current solenoid: 2 A (slow blow)
- Safety class
- II
- Power consumption
- <2.5 W (continuous operation), max. 47 W (for 250 ms)
- Operation cycles
- max. 1200/h
- Mechanical life
- > 500 000 operations
- Locking force Fmax
- 1000 N
- Impact energy
- max. 7 J
- Ambient temperature
- –20 °C … +55 °C
- Ex marking
- L II 2G Ex db eb mb IIC T4 Gb,
L II 2D Ex tb IIIC T100°C Db
- Approvals
- BVS 10 ATEX E 053 X
IECEx BVS 11.0030X
f *
d *
Ü *
a *
* depending on the variant
Downloads
Variants / Options
The following variants / options are available on request:
Actuator turned by 90°