Technical data
General technical data
- Applied standards
- EN 60947-5-1, EN IEC 60079-0, EN 60079-1, EN 60079-31, EN ISO 13849-1, EN ISO 14119
- Enclosure
- thermoplastic, glass-fibre reinforced, shockproof, self-extinguishing UL 94 V-0
- Actuator
- stainless steel 1.4301
- Switch type
- type 2
- Coding level
- low coding
- Degree of protection
- IP65 (IEC/EN 60529)
- B10d (10 % load)
- 2 million
- TM
- max. 20 years
- Contact material
- silver
- Switching system
- slow action, positive break NC contacts A
- Switching elements
- 1 NC/1 NO contact or 2 NC/1 NO, type Zb
- Connection
- screw connection terminals or cable H05VV-F, 4 x 0.75 mm²
- Rated impulse withstand voltage Uimp
- 4 kV
- Rated insulation voltage Ui
- 250 V
- Conventional thermal current Ithe
- 3 contacts: 3 A;
2 contacts: T6: 6 A, T5: 3 A
- Rated operating current/voltage Ie/Ue
- 3 contacts: 3 A/250 VAC; 0.25 A/230 VDC
2 contacts: 6 A/250 VAC; 0.25 A/230 VDC
- Utilisation category
- AC-15; DC-13
- Short-circuit protection
- 3 contacts: 3 A gG fuse,
2 contacts: 6 A gG fuse
- Positive break travel
- 9 mm
- Ambient temperature
- 3 contacts: T6: –20 °C … +55 °C; T5: –20 °C … +70 °C
2 contacts: T6: –20 °C … +65 °C, T5: –20 °C … +75 °C, +90 °C with max. 3 A
- Mechanical life
- > 1 million operations
- Impact energy
- max. 7 J
- Ex marking
- 3 contacts:
L II 2G Ex de IIC T6/T5 Gb,
L II 2D Ex tb IIIC T80 °C/T95 °C Db
IECEx Ex de IIC T6/T5 Gb,
Ex tb IIIC T80 °C/T95 °C Db
2 contacts:
L II 2G Ex db IIC T6/T5 Gb,
L II 2D Ex tb IIIC T80 °C/T95 °C Db
- Approvals
- 3 contacts:
PTB 13 ATEX 1008 X
IECEx PTB 13.0014X
Ü a
2 contacts:
PTB 03 ATEX 1068 X*
IECEx PTB 06.0053X*
d
*referring to the switch insert