Technical data

Applied standards
EN 60947-5-2, EN 60947-5-7, EN IEC 60079-0, EN IEC 60079-7, EN 60079-18, EN 60079-31
Enclosure
aluminium die-cast, corrosion-resistant, powder-coated, anthracite grey, similar to RAL 7016
Cover
stainless steel 1.4401, powder-coated, signal yellow, similar to RAL 1003
Degree of protection
IP65 (IEC/EN 60529)
Switching system
Hall sensor with analogue output
Linearity
2 %
Connection
Cage clamps
Cable cross-section
max. 0.08 … 2.5 mm², AWG 28 … 12
Cable entry
1 x M20 x 1.5 (for cable glands only)
Clamping range
4 … 13 mm
Over temperature protection
2 thermal lead fuses, monitoring via μ controller + NTC
Rated operating voltage Ue
24 VDC
Rated operating voltage range UB
18 … 30 VDC
Rated output current
Q2: ≤ 100 mA short-circuit protected
Voltage drop at Ie
2 V
Attendance delay tv
< 500 ms
Short-circuit protection
internal fuse 0.375 A F
Ambient temperature
T6: –20 °C … +50 °C;
T5: –20 °C … +60 °C
Mechanical life
> 1 million operations
Impact energy
max. 7 J
Ex marking
L II 2G Ex e mb IIC T6/T5 Gb,
L II 2D Ex tb IIIC T80 °C/T95°C Db
IECEx Ex e mb IIC T6/T5 Gb,
Ex tb IIIC T80°C/T95°C Db
Approvals
BVS 15 ATEX E020
IECEx BVS 15.0028

Downloads

Loading...
Choose the type of download
Mounting and wiring instructions – Ex HS 98

German, English, French, Italian, Portuguese

PDF 2 MB 13.11.2025
Please go to the relevant product pages for additional downloads.

Variants / Options

The following variants / options are available on request:

  • Further actuators

to your contact persons