Ex position switch
Ex 97-3G/D
Ex zone 2 and 22
Thermoplastic enclosure
High degree of protection IP66 / IP67
Mounting details to EN 50047
Wiring compartment
Slow action
Actuator can be repositioned by 4 x 90°
Rocking lever can be repositioned by 10° steps
Notes
1 Ex"e" cable gland M20x1.5 included in delivery.
Loading...
Found 13 results
Product
Product
Standard Version
Product
Product
Product
Standard Version
Product
Product
Product
Product
Product
Product
Product
Standard Version
Loaded 12 from 13 results
more products
Technical data
General technical data
- Applied standards
- EN IEC 60079-0, EN 60079-1, EN IEC 60079-7, EN 60079-31, EN 60947-5-1, EN ISO 13849-1, EN ISO 14119
- Enclosure
- thermoplastic, glass-fibre reinforced, shockproof, self-extinguishing UL 94 V-0
- Cover
- thermoplastic, glass-fibre reinforced, shockproof, self-extinguishing UL 94 V-0
- Sealing
- silicone
- Switch type
- type 1
- Coding level
- no coding
- Tightening torque
- cover screws: 0.4 … 0.5 Nm
- Degree of protection
- IP66 / IP67 (EN IEC 60079-0 + IEC/EN 60529)
- B10d (10 % load)
- 2 million
- TM
- max. 20 years
- Contact material
- Silver, nickel-plated
- Switching system
- slow action, positive break NC contacts A; positive break depends on the actuator used
- Switching elements
- 1 NC/1 NO, 2 NC or 1 NC/1 NO contact with contact overlapping, type Zb
- Connection
- screw connection terminals
- Cable cross-section
- min. 0.75 mm² (AWG 18), max. 1.5 mm² (AWG 16), incl. conductor ferrules
- Cable entry
- M20 x 1.5; screwing depth max. 9 mm; use only Ex approved and certified cable glands with min. degree of protection IP66/IP67 and suitable for the specified ambient temperature range
- Utilisation category
- AC-15
- Rated operating current/voltage Ie/Ue
- max. 3 A or 6 A / max. 250 V
- Degree of pollution
- 3
- Mechanical life
- 1 million operations
- Impact energy
- max. 4 J
- Temperature class
- T6
- Ambient temperature
- –20 °C … +45 °C max. 6 A,
–20 °C … +60 °C max. 3 A
- Short-circuit protection
- 3 A / 6 A gG/gN fuse
- Safety class
- II
- Ex marking
- L II 3G Ex dc ec IIC T6 Gc X,
L II 3D Ex tc IIIC T80 °C Dc X