Ex foot switch
Ex GFS 3
Ex zone 1 and 21
3-pedal type
Metal enclosure
With protective shield
Max. 2 contacts per pedal
Low pedal height
With pre-wired cable
Attention: Please state required international approvals with your order!
Loading...
Found 3 results
Product
Product
Product
Loaded 3 from 3 results
Technical data
General technical data
- Applied standards
- EN 60947-5-1, EN IEC 60079-0, EN 60079-1, EN 60079-31, EN ISO 13849-1
- Enclosure
- aluminium die-cast, powder-coated
- Pedal
- thermoplastic, glass-fibre reinforced, shockproof, self-extinguishing UL 94 V-0
- Protective shield
- aluminium die-cast, powder-coated
- Degree of protection
- IP65 (IEC/EN 60529)
- B10d (10 % load)
- Ex GFS 3: 2 million
- TM
- Ex GFS 3: max. 20 years
- Connection
- cable H05VV-F
- Cable cross-section
- 3 or 4 x 0.75 mm² (incl. conductor ferrules)
- Cable length
- 3 m
- Contact material
- silver
- Switching system
- Ex GFS: slow action, positive break NC contacts A
Ex GFSM: snap action
- Switching elements
- Ex GFS: 1 NC/1 NO contact, type Zb
Ex GFSM: change-over contact with single break C or 1 NC/1 NO contact, type Za
- Switch insert
- Ex GFS: Ex 14
Ex GFSM: type C: ExM 14, type Za: ExM 14 1Ö/1S
- Utilisation category
- AC-15; DC-13
- Rated operating current/voltage Ie/Ue
- Ex GFS 3: 6 A/250 VAC; 0.25 A/230 VDC
Ex GFSM 3: 5 A/250 VAC; 0.16 A/230 VDC
Ex GFSM 3 1ÖS/1ÖS/1ÖS: 5 A/250 VAC; 0.2 A/230 VDC
- Short-circuit protection
- Ex GFS 3: 6 A gG/gN fuse
Ex GFSM 3: 5 A gG/gN fuse
- Ambient temperature
- Ex GFS:
T6: –20 °C … +60 °C,
T5: –20 °C … +75 °C
Ex GFSM:
T6: –20 °C … +60 °C
- Mechanical life
- > 1 million operations
- Impact energy
- max. 7 J
- Approvals
- PTB 11 ATEX 1002 X
IECEx PTB 11.0090X *
f *
a *
* depending on the variant
Downloads
Variants / Options
The following variants / options are available on request:
Special finish in RAL colour tones