Ex command device
Ex BF 80
Ex zone 1 and 21
Cold-resistant down to -60 °C
Different actuating elements like push buttons, selector or key switches available
3 different enclosure sizes
Loading...
Found 34 results
Product
Standard Version
Product
Product
Product
Product
Product
Product
Standard Version
Product
Standard Version
Product
Product
Product
Standard Version
Product
Loaded 12 from 34 results
more products
Technical data
General technical data
- Applied standards
- EN IEC 60079-0, EN 60079-1, EN IEC 60079-7, EN 60079-31, EN ISO 13849-1
- Enclosure
- polyester resin, glass-fibre reinforced
- Sealing
- silicone
- Tightening torque
- cover screws: max. 1 Nm
connecting thread of cable gland: max. 3 Nm
cap nut of cable gland: max. 2 Nm
- Degree of protection
- IP66 (IEC/EN 60529)
- B10d (10 % load)
- 6050
- TM
- max. 20 years
- Switching system
- slow action, positive break NC contacts A
- Connection
- screw connection terminals
- Cable cross-section
- max. 2.5 mm² (incl. conductor ferrules)
- Cable entry
- 1 x M25 x 1.5 (for cable glands only)
- Clamping range
- 7 … 17 mm
- Mechanical life
- 50 000 operations
- Impact energy
- max. 7 J (LDT/LM: max. 4 J)
- Rated insulation voltage Ui
- 550 V
- Rated operating current/voltage Ie/Ue
- Contact element: AC-12: 6 A/400 VAC; AC-15: 2.5 A/400 VAC; DC-13: 1.25 A/250 VDC
- Switching capacity
- Contact element: AC-12: 3000 VA; AC-15: 1000 VA; DC-13: 110 W
- Rated operating current Ie
- Lighting element: max. 10 mA
- Rated operating voltage Ue
- Lighting element:
12 … 240 V at max. 60°C
12 … 120 V at max. 65°C
- Power consumption
- Lighting element: max. 1 W
- Frequency range
- Lighting element: 0 … 60 Hz
- Temperature class
- T6 / T5
- Ambient temperature
- T6: –60 °C … +50 °C;
T5: –60 °C … +65 °C
- Ex marking
- L II 2G Ex db eb IIC T6/T5 Gb,
L II 2D Ex tb IIIC T80 °C/T95 °C Db
IECEx Ex db eb IIC T6/T5 Gb,
Ex tb IIIC T80 °C/T95 °C Db
- Approvals
- PTB 10 ATEX 1018
IECEx PTB 12.0029