Ex command device
Ex 14
Ex zone 1 and 21
Control panel mounting
Thermoplastic enclosure with cable
Compact design
Mounting hole diameter 22.5 mm
Attention: Please state required international approvals with your order!
Loading...
Found 31 results
Product
Standard Version
Product
Product
Product
Product
Product
Product
Product
Product
Product
Product
Product
Loaded 12 from 31 results
more products
Technical data
General technical data
- Applied standards
- EN 60947-5-1, EN ISO 13849-1, EN IEC 60079-0, EN 60079-1, EN 60079-31, emergency stop devices: EN 60947-5-5 and EN ISO 13850
- Enclosure
- thermoplastic, glass-fibre reinforced, shockproof, self-extinguishing UL 94 V-0
- Degree of protection
- device: IP65 (EN IEC 60079-0 + IEC/EN 60529)
actuator: IP65/IP67 (IEC/EN 60529)
- B10d (10 % load)
- 2 million;
QRB…, QRSK…: > 100 000;
RUV…, QRUV…: > 12 100
- TM
- max. 20 years
- Contact material
- silver
- Switching system
- slow action, positive break NC contacts A
- Switching elements
- 1 NC/1 NO contact or 2 NC contacts, type Zb
- Connection
- cable H05VV-F
- Cable cross-section
- 4 x 0.75 mm²
- Rated impulse withstand voltage Uimp
- 4 kV
- Rated insulation voltage Ui
- 250 V
- Conventional thermal current Ithe
- T6: 6 A, T5: 3 A
- Rated operating current/voltage Ie/Ue
- 6 A/250 VAC; 0.25 A/230 VDC
- Utilisation category
- AC-15; DC-13
- Short-circuit protection
- 6 A gG fuse
- Ambient temperature
- T6: –20 °C … +65 °C,
T5: –20 °C … +75 °C, +90 °C with max. 3 A
emergency-stop push button: T5: –20 °C … +75 °C
- Mechanical life
- > 1 million operations;
QRB…, QRSK…: > 50 000 operations;
RUV…, QRUV…: > 6050 operations
- Operation cycles
- max. 1800/h
- Impact energy
- max. 4 J
- Ex marking
- L II 2G Ex db IIC T6/T5 Gb,
L II 2D Ex tb IIIC T80 °C/T95 °C Db
- Approvals
- PTB 03 ATEX 1070 X
IECEx PTB 06.0098X
f d a
Downloads
Variants / Options
The following variants / options are available on request:
Gold-plated contacts
Cable entry on side
Cold-resistant version down to -40 °C