Ex command device

Ex 14


  • Ex zone 1 and 21

  • Control panel mounting

  • Thermoplastic enclosure with cable

  • Compact design

  • Mounting hole diameter 22.5 mm

  • Attention: Please state required international approvals with your order!

Technical data

Applied standards
EN 60947-5-1, EN ISO 13849-1, EN IEC 60079-0, EN 60079-1, EN 60079-31, emergency stop devices: EN 60947-5-5 and EN ISO 13850
Enclosure
thermoplastic, glass-fibre reinforced, shockproof, self-extinguishing UL 94 V-0
Degree of protection
device: IP65 (EN IEC 60079-0 + IEC/EN 60529)
actuator: IP65/IP67 (IEC/EN 60529)
B10d (10 % load)
2 million;
QRB…, QRSK…: > 100 000;
RUV…, QRUV…: > 12 100
TM
max. 20 years
Contact material
silver
Switching system
slow action, positive break NC contacts A
Switching elements
1 NC/1 NO contact or 2 NC contacts, type Zb
Connection
cable H05VV-F
Cable cross-section
4 x 0.75 mm²
Rated impulse withstand voltage Uimp
4 kV
Rated insulation voltage Ui
250 V
Conventional thermal current Ithe
T6: 6 A, T5: 3 A
Rated operating current/voltage Ie/Ue
6 A/250 VAC; 0.25 A/230 VDC
Utilisation category
AC-15; DC-13
Short-circuit protection
6 A gG fuse
Ambient temperature
T6: –20 °C … +65 °C,
T5: –20 °C … +75 °C, +90 °C with max. 3 A
emergency-stop push button: T5: –20 °C … +75 °C
Mechanical life
> 1 million operations;
QRB…, QRSK…: > 50 000 operations;
RUV…, QRUV…: > 6050 operations
Operation cycles
max. 1800/h
Impact energy
max. 4 J
Ex marking
L II 2G   Ex db IIC T6/T5 Gb,
L II 2D   Ex tb IIIC T80 °C/T95 °C Db
Approvals
PTB 03 ATEX 1070 X
IECEx PTB 06.0098X
f d a

Downloads

Loading...
Choose the type of download
Mounting and wiring instructions – Ex 14

German, English, French, Italian, Portuguese

PDF 4 MB 23.01.2026
Please go to the relevant product pages for additional downloads.

Variants / Options

The following variants / options are available on request:

  • Gold-plated contacts

  • Cable entry on side

  • Cold-resistant version down to -40 °C

to your contact persons