Emergency pull-wire switch
ZS 92 S 02 VD Si-Bus B -40°C ... +70°C IP66/67 Extreme
Article no.: 1363023
contact usProduct features
Suitable for installation of a safety bus module
With integrated 8-pole Phoenix multi-way connector and bracket for safety bus module
Temperature resistant from -40 °C to +70 °C
High degree of protection IP66 / IP67
Corrosion-resistant aluminium enclosure
Screws made of stainless steel
Wire length up to 2 x 100 m
Release by lever
B = Reset lever on back
Rear and base mounting possible
Wire pull and breakage detection
Notes
The safety bus module is not included in delivery.
Technical data
General technical data
Applied standards
EN 60947-5-1, EN 60947-5-5, EN ISO 13850, EN ISO 13849-1, EN 60529, EN 620-5.7.2.9, AS 1755-2000-2.7.9.1, AS/NZS 4024.3610:2015-2.10.6.2
Enclosure
aluminium die-cast, corrosion-resistant, powder-coated, passivated, shockproof, anthracite grey, similar to RAL 7016
Cover
aluminium die-cast, corrosion-resistant, powder-coated, passivated, shockproof, signal yellow, similar to RAL 1003
Actuating lever
aluminium die-cast, corrosion-resistant, powder-coated, passivated, shockproof, signal red, similar to RAL 3001
Reset lever
aluminium die-cast, corrosion-resistant, powder-coated, passivated, shockproof, sky blue, similar to RAL 5015
Screws
stainless steel
Tightening torque
cover screws: max. 2.5 Nm
actuator screws: max. 6 Nm
Degree of protection
IP66/IP67 (IEC/EN 60529)
B10d (10 % load)
100 000
TM
max. 20 years
Switching system
snap action, positive break NC contacts A
Switching elements
2 NC contacts, type Zb
Connection
screw connection terminals, basic strip to connect Dupline Safe input module with plug-in connector (see accessories)
Cable cross-section
0.5 ... 2.5 mm² (incl. conductor ferrules)
Cable entry
2 x M25 x 1.5
Rated impulse withstand voltage Uimp
4 kV
Rated insulation voltage Ui
250 V
Conventional thermal current Ithe
6 A
Conditional short-circuit current
1100 A
Rated operating current/voltage Ie/Ue
6 A/250 VAC
Utilisation category
AC-15
Short-circuit protection
6 A gG fuse
Mechanical life
> 50 000 operations
Max. wire length
2 x 100 m
Note
At 3 m distance intermediate wire supports are required. Two compensation springs type ZS 92 S must be installed, see accessories.
Ambient temperature
with Si-Bus –40 °C … +70 °C;
without Si-Bus –40 °C … +85 °C
Degree of pollution
3
Actuating force
actuating lever approx. 30 N; reset lever approx. 40 N
Approvals
ßda