Emergency pull-wire switch

ZS 92 S 02 VD Si-Bus B -40°C ... +70°C IP66/67 Extreme

Article no.: 1363023

contact us

Product features

Safety
  • Suitable for installation of a safety bus module

  • With integrated 8-pole Phoenix multi-way connector and bracket for safety bus module

  • Temperature resistant from -40 °C to +70 °C

  • High degree of protection IP66 / IP67

  • Corrosion-resistant aluminium enclosure

  • Wire length up to 2 x 100 m

  • Release by lever

  • B = Reset lever on back

  • Rear and base mounting possible

  • Wire pull and breakage detection

Notes

  • The safety bus module is not included in delivery.

Technical data

Applied standards
EN 60947-5-1, EN 60947-5-5, EN ISO 13850, EN ISO 13849-1, EN 60529, EN 620-5.7.2.9, AS 1755-2000-2.7.9.1, AS/NZS 4024.3610:2015-2.10.6.2
Enclosure
aluminium die-cast, corrosion-resistant, powder-coated, passivated, shockproof, anthracite grey, similar to RAL 7016
Cover
aluminium die-cast, corrosion-resistant, powder-coated, passivated, shockproof, signal yellow, similar to RAL 1003
Actuating lever
aluminium die-cast, corrosion-resistant, powder-coated, passivated, shockproof, signal red, similar to RAL 3001
Reset lever
aluminium die-cast, corrosion-resistant, powder-coated, passivated, shockproof, sky blue, similar to RAL 5015
Screws
stainless steel
Tightening torque
cover screws: max. 2.5 Nm
actuator screws: max. 6 Nm
Degree of protection
IP66/IP67 (IEC/EN 60529)
B10d (10 % load)
100 000
TM
max. 20 years
Switching system
snap action, positive break NC contacts A
Switching elements
2 NC contacts, type Zb
Connection
screw connection terminals, basic strip to connect Dupline Safe input module with plug-in connector (see accessories)
Cable cross-section
0.5 ... 2.5 mm² (incl. conductor ferrules)
Cable entry
2 x M25 x 1.5
Rated impulse withstand voltage Uimp
4 kV
Rated insulation voltage Ui
250 V
Conventional thermal current Ithe
6 A
Conditional short-circuit current
1100 A
Rated operating current/voltage Ie/Ue
6 A/250 VAC
Utilisation category
AC-15
Short-circuit protection
6 A gG fuse
Mechanical life
> 50 000 operations
Max. wire length
2 x 100 m
Note
At 3 m distance intermediate wire supports are required. Two compensation springs type ZS 92 S must be installed, see accessories.
Ambient temperature
with Si-Bus –40 °C … +70 °C;
without Si-Bus –40 °C … +85 °C
Degree of pollution
3
Actuating force
actuating lever approx. 30 N; reset lever approx. 40 N
Approvals
ßda

Dimensional drawing

Further drawings

Contact diagram

S1 - Switch insert 1

Switching diagram

U Latching point
V Wire breakage detection
W Wire pull detection
S1 - Switch insert 1

Installation of Si-Bus

Downloads

Loading...
Choose the type of download
Mounting and wiring instructions – ZS 92 S Extreme

German, English, French, Italian, Portuguese, Russian

PDF3 MB 02.12.2025
SIL application notes – ZS 92 S

English

PDF2 MB 25.11.2025
Loading...

Other interesting products

Alternative version with explosion protection

ExSafety

Version with thermoset enclosure

Safety

Emergency pull-wire switch

ZS 92 S 02 VD Si-Bus B -40°C ... +70°C IP66/67 Extreme

Article no.: 1363023

contact us