Product features
Thermoplastic enclosure
sWave® wireless technology
Can be combined with 3-wire PNP sensors 24 VDC or external sensors or NO contacts with gold contacts
No wiring and cable laying required
External power supply via M12 socket
Output signal can be individually configured at the receiver
LBT - Listen before Talk Firmware
Technical data
General technical data
Applied standards
EN 60947-5-1, EN 61000-6-3, EN 300 220-2, EN 301 489-3, EN 62479
Enclosure
ABS, UL 94 HB, RAL 9005
Antenna
internal antenna
Tightening torque
enclosure mounting screws: max. 1.5 Nm
cover screws: max. 1.5 Nm
Degree of protection
IP65 (IEC/EN 60529), only with plugged cables and/or with closed protective caps
Voltage source
24 VDC
Connection
Sensors: plug-in connector 4 x M12 x 1, 4-pole
power supply: 1 x M12 socket
Connectable devices
IS M8, IS M12, IS M18, IS M30, external switches using the connecting cable
Safety class
III
Ambient temperature
–20 °C … +65 °C
Type of installation
mount on an even surface
Mounting position
any
Mounting
screw connection
Switching frequency
max. 5 Hz
Rated operating voltage range UB
18 … 30 VDC Pin 1 and Pin 3, socket M12
Rated insulation voltage Ui
75 VDC
Rated impulse withstand voltage Uimp
0.5 kV
Rated operating current Ie
2.5 mA
Voltage drop Ue - Uout
3.5 V with 4 x 50 mA sensor current
Load current
max. 50 mA per sensor connection (not short-circuit proof)
Switching points
> 5 VDC (E1 - E4)
Actuating time
min. 80 ms
Note
transmission of battery voltage and switching condition
Wireless technology
General
Frequency
916.5 MHz (Japan)
Data rate
66 kbps
Channel bandwidth
520 kHz
Modulation type
2-FSK
Protocol
sWave®
Wireless approvals
Japan: ? ARIB STD-T108: 204-610002
Function
Telegram rate
max. 1440 telegrams with repetitions/h
Transmission power
< 1 mW
Wireless range
max. 150 m outdoors, max. 20 m indoors
Note
status signal – can be individually configured via radio receiver (delivery state: without status signal)