Ex position switch
Ex 98-3G/D
Ex zone 2 and 22
Metal enclosure
Design to EN 50041
Wiring compartment
Slow action
Actuator can be repositioned by 4 x 90°
Rocking lever can be repositioned by 10° steps
Loading...
Found 13 results
Product
Product
Product
Standard Version
Product
Product
Product
Product
Product
Product
Product
Product
Product
Standard Version
Loaded 12 from 13 results
more products
Technical data
General technical data
- Applied standards
- EN 60947-5-1, EN IEC 60079-0, EN 60079-1, EN IEC 60079-7, EN 60079-31, EN ISO 13849-1, EN ISO 14119
- Enclosure
- aluminium die-cast, corrosion-resistant, powder-coated, anthracite grey, similar to RAL 7016
- Cover
- aluminium die-cast, powder-coated, signal yellow, similar to RAL 1003
- Sealing
- silicone
- Switch type
- type 1
- Coding level
- no coding
- Degree of protection
- IP67 (IEC/EN 60529)
- B10d (10 % load)
- 2 million
- TM
- max. 20 years
- Contact material
- silver
- Switching system
- slow action, positive break NC contacts A; positive break depends on the actuator used
- Switching elements
- 1 NC/1 NO, 2 NC, 1 NC/1 NO contact with overlapping and 2 NC/1 NO, type Zb
- Connection
- screw connection terminals
- Cable cross-section
- min. 0.5 mm² (AWG 20), max. 1.5 mm² (AWG 16), incl. conductor ferrules
- Cable entry
- 1 x M20 x 1.5 (for cable glands only)
- Clamping range
- 7 ... 13 mm (without reduction sealing insert)
4 ... 8 mm (with reduction sealing insert)
- Rated impulse withstand voltage Uimp
- 4 kV
- Rated insulation voltage Ui
- 2 contacts: 400 V, 3 contacts: 250 V
- Conventional thermal current Ithe
- 2 contacts: 6 A, 3 contacts: 1.5 A
- Rated operating current/voltage Ie/Ue
- 2 contacts: 6 A/250 VAC; 0.25 A/230 VDC
3 contacts: 1.5 A/250 VAC; 0.2 A/250 VDC
- Utilisation category
- AC-15; DC-13
- Short-circuit protection
- 2 contacts: 6 A gG fuse
3 contacts: 1.5 A gG fuse
- Ambient temperature
- T6: –20 °C … +40 °C;
T5: –20 °C … +60 °C
- Mechanical life
- > 1 million operations
- Operation cycles
- max. 1800/h
- Repeat accuracy of switching points
- ± 0.1 mm
- Impact energy
- max. 7 J
- Ex marking
- L II 3G Ex dc ec IIC T6/T5 Gc X,
L II 3D Ex tc IIIC T80 °C/T95 °C Dc