Product features
Ex zone 22
Metal enclosure
2 contacts
Position indicator and integrated emergency-stop push button
Wire length up to 100 m
Spring force variant: 100 N
Lever for release and position indication
Watertight collar
Wire pull and breakage detection
Technical data
General technical data
- Applied standards
- EN IEC 60079-0, EN 60079-31, EN 60947-5-1, EN 60947-5-5, EN ISO 13849-1, EN ISO 13850
- Enclosure
- aluminium die-cast, powder-coated, RAL 1003
- Cover
- thermoplastic, glass-fibre reinforced, shockproof, self-extinguishing UL 94 V-0
- Degree of protection
- IP65 (EN IEC 60079-0 + IEC/EN 60529), IP67 (IEC/EN 60529)
- B10d (10 % load)
- 200 000
- TM
- max. 20 years
- Contact material
- silver
- Switching system
- slow action, positive break NC contacts A
- Switching elements
- 1 NC/1 NO contact, type Zb
- Connection
- cable H05VV-F
- Cable cross-section
- 4 x 0.75 mm² (incl. conductor ferrules)
- Cable length
- 3 m
- Rated impulse withstand voltage Uimp
- 4 kV
- Rated insulation voltage Ui
- 250 V
- Conventional thermal current Ithe
- 6 A
- Utilisation category
- AC-15
- Rated operating current/voltage Ie/Ue
- 6 A/250 VAC; 0.25 A/230 VDC
- Short-circuit protection
- 6 A gG/gN fuse
- Ambient temperature
- –20 °C … +65 °C
- Mechanical life
- > 100 000 operations
- Max. wire length
- 100 m
- Note
- At 5 m distance intermediate wire supports are required. One wire thimble is provided.
- Impact energy
- max. 7 J
- Ex marking
- L II 3D Ex tc IIIC T80°C Dc
- Weight
- 956 g
Downloads