Ex safety sensor

Ex RC Si 56 2Ö - LED - 10m

Article no.: 1187207Old article no.: 25653903

contact us

Product features

ExSafety
  • Ex zone 1 and 21

  • Thermoplastic enclosure with cable

  • Long life

  • Reed contacts, coded

  • Actuation from front

  • Attention: Please state required international approvals with your order!

Notes

  • The actuator is not included in the delivery of the switches.

Technical data

Applied standards
EN IEC 60079-0, EN 60079-18, EN 60947-5-1, EN 60947-5-3, EN ISO 13849-1, EN ISO 14119
Enclosure
thermoplastic, glass-fibre reinforced, shockproof, self-extinguishing UL 94 V-0
Sensor type
type 4 interlocking device
Coding level
low coding
Degree of protection
IP67 (IEC/EN 60529)
Switching system
reed contacts
Switching elements
2 NC contacts
Connection
cable 4 x AWG 24 UL
Cable cross-section
4 x 0.22 mm²
Cable length
10 m
Switching voltage
max. 30 VDC
Rated operating current/voltage Ie/Ue
max. 20 mA / 24 VDC
Voltage drop at Ie
max. 3 V
Assured switching distance »OFF« sar 
30 mm
Repeatability
< 0.5 mm
Hysteresis
min. 23 mm
Degree of pollution
3
Safety class
II
Ambient temperature
T6: –20 °C … +70 °C,
T5: –20 °C … +85 °C
Mechanical life
> 1 million operations
Vibration resistance
10 g (10-500 Hz)
Shock resistance
100 g (1 ms, ½ sin)
Bounce duration
max. 2 ms (response time, incl. bounce)
Impact energy
max. 7 J
Ex marking
L II 2G Ex mb IIC T6/T5 Gb
L II 2D Ex mb IIIC T80 °C/T95 °C Db
IECEx Ex mb IIC T6/T5 Gb
Ex mb IIIC T80 °C/ T95 °C Db
Approvals
PTB 08 ATEX 2027 X
IECEx PTB 08.0042 X
fda
Weight
320 g
EN ISO 13849-1
Performance Level PL e
Category
4
B10d (10 % load)
2 million
TM
max. 20 years
MTTFd
> 100 years
DC/DCavg
> 99 %
Note
The safety-related data are only valid in combination with a safety module, e.g. SRM 21 RT2 (mat. no. 1179203).
 

Dimensional drawing

Further drawings

Contact diagram
Axial misalignment

Downloads

Loading...
Choose the type of download
Mounting and wiring instructions – Ex RC Si 56

German, English, French, Italian, Portuguese

PDF2 MB 13.03.2026

Variants / Options

The following variants / options are available on request:

  • Maritime certification to DNV <

to your contact persons
Loading...

Other interesting products

Special version only for gas Ex zone 2 and dust Ex zone 22

ExSafety

Ex safety sensor

Ex RC Si 56 2Ö - LED - 10m

Article no.: 1187207Old article no.: 25653903

contact us