Ex solenoid interlock
Ex STM 295-3G/D
Ex zone 2 and 22
Thermoplastic enclosure
Wiring compartment
Spring-to-lock or power-to-lock principle
Locking force 1000 N
With LED
Notes
1 Ex"e" cable gland M20x1.5 included in delivery.
The actuator is not included in the delivery of the switches.
Loading...
Found 14 results
Product
Product
Product
Product
Standard Version
Product
Product
Product
Product
Product
Product
Product
Product
new
Loaded 12 from 14 results
more products
Technical data
General technical data
- Applied standards
- EN 60947-5-1, EN IEC 60079-0, EN 60079-1, EN IEC 60079-7, EN 60079-18, EN 60079-31, EN ISO 13849-1, EN ISO 14119
- Enclosure
- thermoplastic, glass-fibre reinforced, shockproof, self-extinguishing UL 94 V-0
- Switch type
- type 2
- Coding level
- low coding
- Tightening torque
- cover screws: 0.5 … 0.6 Nm
enclosure mounting screws: 1 … 1.3 Nm
switch inserts M3 screw connection terminals: min. 0.6 Nm
solenoid M3.5 screw connection terminals: min. 0.8 Nm
- Degree of protection
- IP67 (IEC/EN 60529)
- B10d (10 % load)
- 1 million
- TM
- max. 20 years
- Contact material
- silver
- Switching system
- slow action, positive break NC contacts A
- Switching elements
- 1 NC/1 NO contact + 1 NC/1 NO contact or 2 NC + 1 NC/1 NO contact
- Connection
- screw connection terminals
- Cable cross-section
- solenoid: 0.2 … 1.5 mm2 (AWG 24 … 16)
switch inserts: 0.75 … 1.5 mm2 (AWG 18 … 16)
- Cable entry
- 2 x M20 x 1.5; use only Ex approved and certified cable glands with min. degree of protection IP67 and admissible ambient temperature range
- Clamping range
- 7 … 12 mm
- Rated insulation voltage Ui
- 250 V
- Rated impulse withstand voltage Uimp
- 4 kV
- Utilisation category
- AC-15; DC-13
- Short-circuit protection
- 3 A / 1.5 A gG fuse;
direct-current solenoid: 2 A (slow blow)
- Safety class
- II
- Power consumption
- <2.5 W (continuous operation), max. 47 W (for 250 ms)
- Operation cycles
- max. 1200/h
- Mechanical life
- > 500 000 operations
- Locking force Fmax
- 1000 N
- Impact energy
- max. 7 J
- Ambient temperature
- –20 °C … +55 °C
- Ex marking
- L II 3G Ex dc ec mc IIC T4 Gc
L II 3D Ex tc IIIC T100°C Dc
Downloads