Ex pull-wire switch

Ex 61 Z / ExM 61 Z


  • Ex zone 1 and 21

  • Metal enclosure

  • Wall mounting

  • Slow or snap action

  • Pull-wire function

  • Watertight collar W for protection against penetration of dirt available

  • Attention: Please state required international approvals with your order!

Technical data

Applied standards
EN 60947-5-1, EN IEC 60079-0, EN 60079-1, EN 60079-31, EN ISO 13849-1
Enclosure
aluminium die-cast, powder-coated
Cover
steel, powder-coated
Degree of protection
IP65 (IEC/EN 60529)
B10d (10 % load)
Ex 61 Z: 2 million
TM
max. 20 years
Switch insert
Ex 14, ExM 14
Contact material
silver
Switching system
slow or snap action
Switching elements
ExM 61: change-over contact with single break, Form C
Ex 61: 1 NC/1 NO contact, type Zb
Connection
cable H05VV-F
Cable cross-section
3 or 4 x 0.75 mm² (incl. conductor ferrules)
Cable length
3 m
Rated impulse withstand voltage Uimp
4 kV
Rated insulation voltage Ui
250 V
Conventional thermal current Ithe
Ex 61: T6: 6 A; T5: 3 A
ExM 61: 5 A
Rated operating current/voltage Ie/Ue
Ex 61: 6 A/250 VAC, 0.25 A/230 VDC
ExM 61: 5 A/250 VAC, 0.16 A/230 VDC
Utilisation category
AC-15; DC-13
Short-circuit protection
Ex 61: 6 A gG fuse;
ExM 61: 5 A gG fuse
Ambient temperature
Ex 61: T6: –20 °C … +65 °C, T5: –20 °C … +75 °C, +90 °C with max. 3 A
ExM 61: –20 °C … +60 °C
Mechanical life
> 1 million operations
Operation cycles
max. 1800/h
Repeat accuracy of switching points
± 0.1 mm
Impact energy
max. 7 J
Ex marking
Ex 61:
L II 2G Ex db IIC T6/T5 Gb,
L II 2D Ex tb IIIC T80 °C/T95 °C Db

ExM 61:
L II 2G Ex d IIC T6 Gb,
L II 2D Ex tb IIIC T80 °C Db IP65
Approvals
Ex 61:
PTB 03 ATEX 1070 X*
IECEx PTB 06.0098X*
d


ExM 61:
PTB 03 ATEX 1069 X*


*referring to the switch insert

Downloads

Loading...
Choose the type of download
Mounting and wiring instructions – Ex/ExM 61 Z

German, English, French, Italian, Portuguese

PDF 4 MB 03.02.2026
Please go to the relevant product pages for additional downloads.
Loading...