Technical data
General technical data
Applied standards
EN 60947-5-2, EN 60947-5-7
Enclosure
aluminium die-cast, powder-coated
Degree of protection
IP67 (IEC/EN 60529)
Switching system
Hall sensor with analogue output
Linearity
2 %
Connection
Cage clamps
Cable cross-section
max. 0.08 … 2.5 mm², AWG 28 … 12
Cable entry
1 x M20 x 1.5
Over temperature protection
monitoring via μ controller + NTC
Rated operating voltage Ue
24 VDC
Rated operating voltage range UB
18 … 30 VDC
Rated output current
Q2: ≤ 100 mA short-circuit protected
Voltage drop at Ie
2 V
Attendance delay tv
< 500 ms
Short-circuit protection
internal fuse 0.375 A F
Ambient temperature
–20 °C … +60 °C
Mechanical life
> 1 million operations