Ex position switch
Ex 99
Ex zone 1 and 21
Thermoplastic enclosure
Cold-resistant down to -60 °C
High degree of protection IP66 / IP67 / IP69
Suitable for the food processing industry
Design to EN 50041
Wiring compartment
Slow or snap action
Actuator can be repositioned by 4 x 90°
Rocking lever can be repositioned by 10° steps
Notes
1 Ex"e" cable gland M20x1.5 included in delivery.
Loading...
Found 30 results
Product
Standard Version
Product
Standard Version
Product
Product
Standard Version
Product
Product
Product
Product
Standard Version
Product
Product
Product
Standard Version
Product
Loaded 12 from 30 results
more products
Technical data
General technical data
- Applied standards
- EN 60947-5-1, EN IEC 60079-0, EN 60079-1, EN IEC 60079-7, EN 60079-31, EN ISO 13849-1, EN ISO 14119
- Enclosure
- thermoplastic, glass-fibre reinforced, shockproof, self-extinguishing UL 94 V-0
- Cover
- thermoset, glass-fibre reinforced, shockproof, self-extinguishing UL 94 V-0
- Sealing
- silicone
- Switch type
- type 1
- Coding level
- no coding
- Tightening torque
- cover screws: 1.5 … 2 Nm
- Degree of protection
- IP66 (EN IEC 60079-0 + IEC/EN 60529)
IP67, IP69 (IEC/EN 60529)
IP69K (ISO 20653)
- B10d (10 % load)
- 2 million
- TM
- max. 20 years
- Contact material
- Silver, nickel-plated
- Switching system
- slow or snap action, positive break NC contacts A; positive break depends on the actuator used
- Switching elements
- 1 NC/1 NO, 2 NC, 2NO or 1 NC/1 NO contact with contact overlapping, type Zb
- Connection
- screw connection terminals
- Cable cross-section
- min. 0.75 mm² (AWG 18), max. 1.5 mm² (AWG 16), incl. conductor ferrules
- Cable entry
- M20 x 1.5; screwing depth max. 9 mm; use only Ex approved and certified cable glands with min. degree of protection IP66 and suitable for the specified ambient temperature range
- Clamping range
- 7 … 12 mm
- Utilisation category
- AC-15
- Rated operating current Ie
- max. 2 A or 4 A X
- Rated operating voltage Ue
- max. 500 VAC, 2Ö/2S: max. 400 VAC
max. 250 VAC for unequal potential
- Degree of pollution
- 3
- Mechanical life
- > 1 million operations
- Impact energy
- max. 7 J down to -40 °C, max. 4 J down to -60 °C
- Temperature class
- T6
- Ambient temperature
- –60 °C … +55 °C max. 4 A, +60 °C max. 2 A
- Short-circuit protection
- 2 A / 4 A gG fuse
- Safety class
- II
- Ex marking
- L II 2G Ex db eb IIC T6 Gb,
L II 2D Ex tb IIIC T80 °C Db
IECEx Ex db eb IIC T6 Gb,
Ex tb IIIC T80 °C Db
- Approvals
- BVS 16 ATEX E113 X
IECEx BVS 16.0076X
f d a <