Ex position switch
Ex 13
Ex zone 1 and 21
Thermoplastic enclosure with cable
Suitable for in-line mounting, depends on the actuator used
Slow action
Attention: Please state required international approvals with your order!
Loading...
Found 60 results
Product
Product
Standard Version
Product
Product
Product
Product
Standard Version
Product
Product
Product
Product
Product
Product
Loaded 12 from 60 results
more products
Technical data
General technical data
- Applied standards
- EN 60947-5-1, EN IEC 60079-0, EN 60079-1, EN 60079-31, EN ISO 13849-1, EN ISO 14119
- Enclosure
- thermoplastic, glass-fibre reinforced, shockproof, self-extinguishing UL 94 V-0
- Switch type
- type 1
- Coding level
- no coding
- Degree of protection
- IP65 (EN IEC 60079-0 + IEC/EN 60529), IP67 (IEC/EN 60529)
- B10d (10 % load)
- 2 million
- TM
- max. 20 years
- Contact material
- silver
- Switching system
- slow action, positive break NC contacts A; positive break depends on the actuator used
- Switching elements
- 1 NC/1 NO contact, type Zb
- Connection
- cable H05VV-F
- Cable cross-section
- 4 x 0.75 mm² (incl. conductor ferrules)
- Rated impulse withstand voltage Uimp
- 4 kV
- Rated insulation voltage Ui
- 250 V
- Conventional thermal current Ithe
- T6: 6 A, T5: 3 A
- Rated operating current/voltage Ie/Ue
- 6 A/250 VAC; 0.25 A/230 VDC
- Utilisation category
- AC-15; DC-13
- Short-circuit protection
- 6 A gG/gN fuse
- Safety class
- II
- Ambient temperature
- T6: –20 °C … +65 °C,
T5: –20 °C … +75 °C, +90 °C with max. 3 A
- Mechanical life
- > 1 million operations
- Operation cycles
- max. 1800/h
- Repeat accuracy of switching points
- ± 0.1 mm
- Contact opening
- max. 2 x 4 mm
- Impact energy
- max. 7 J
- Ex marking
- L II 2G Ex db IIC T6/T5 Gb,
L II 2D Ex tb IIIC T80 °C/T95 °C Db
IECEx Ex db IIC T6/T5 Gb,
Ex tb IIIC T80 °C/T95 °C Db
- Approvals
- PTB 03 ATEX 1068 X
IECEx PTB 06.0053X
f d a
Downloads
Variants / Options
The following variants / options are available on request:
Gold-plated contacts
Cable entry on side
Mechanical latching
Other cable types
Special version only for dust Ex zone 22