Ex solenoid interlock

Ex STM 515 11/11 R L

Article no.: 1397480

contact us

Product features

ExSafety
  • Ex zone 1 and 21

  • High degree of protection IP66 / IP67

  • Corrosion-resistant aluminium enclosure

  • Wiring compartment

  • Spring-to-lock principle

  • Actuator head can be repositioned by 4 x 90°

Notes

  • 1 additional cable gland M20x1.5 is included in delivery.

  • The actuator is not included in the delivery of the switches.

Technical data

Applied standards
EN 60947-5-1, EN IEC 60079-0, EN 60079-1, EN IEC 60079-7, EN 60079-18, EN 60079-31, EN ISO 14119, EN ISO 13849-1
Enclosure
aluminium die-cast, corrosion-resistant, shockproof, powder-coated, passivated, anthracite grey, similar to RAL 7016
Cover
aluminium die-cast, corrosion-resistant, shockproof, powder-coated, passivated, signal yellow, similar to RAL 1003
Actuator head
thermoset, glass-fibre reinforced, shockproof, self-extinguishing UL 94 V-0
Screws
stainless steel
Switch type
type 2
Coding level
low coding
Tightening torque
cover screws: max. 2.5 Nm
actuator head: max. 2.5 Nm
enclosure mounting screws: 8 Nm
switch inserts M3 screw connection terminals: min. 0.6 Nm
solenoid M3.5 screw connection terminals: min. 0.8 Nm
Degree of protection
IP66/IP67 (IEC/EN 60529)
B10d (6.7 % load)
1.5 million
TM
max. 20 years
Mounting
4 x M6 cylinder head screw (e.g. DIN 912 / ISO 4762)
Mounting position
any
Safety class
I
Switching system
slow action, positive break NC contacts A
Switching elements
1 NC/1 NO contact + 1 NC/1 NO contact, type Zb
Switch insert
2 x Ex 95
Contact material
silver
Connection
screw connection terminals
Cable cross-section
solenoid: 0.5 … 1.5 mm2 (AWG 20 … 16)
switch inserts: 0.75 … 1.5 mm2 (AWG 18 … 16)
Clamping range
7 … 12 mm
Cable entry
2 x M20 x 1.5; use only Ex approved and certified cable glands with min. degree of protection IP66/67 and admissible ambient temperature range of -20 °C … +70 °C
Rated insulation voltage Ui
250 V
Rated impulse withstand voltage Uimp
4 kV
Conventional thermal current Ithe
6 A
Conditional short-circuit current
1000 A
Utilisation category
AC-15; DC-13
Rated operating current/voltage Ie/Ue
enabling/signalling contacts: 6 A/250 VAC; 0.25 A/230 VDC;
direct-current solenoid: 0.08 A / 24 VDC +10 %/–15 %
Short-circuit protection
6 A gG fuse;
direct-current solenoid: 2 A (slow blow)
Power consumption
<2.5 W (continuous operation), max. 47 W (for 250 ms)
Locking force Fmax
5500 N
Locking force FZh
4000 N
Actuating speed
≤ 0.3 m/s
Actuating force / Latching force
≥ 40 N (retraction and extension of actuator)
Operation cycles
max. 900/h
Mechanical life
1 million operations
Impact energy
max. 7 J
Ambient temperature
–20 °C … +55 °C
Degree of pollution
3
Ex marking
L II 2G   Ex db eb mb IIC T4 Gb,
L II 2D   Ex tb IIIC T100°C Db
Approvals
BVS 23 ATEX E 025 X
IECEx BVS 23.0013X
aß

Dimensional drawing

Further drawings

Contact diagram

A positive break
P actuated
Q not actuated
Æ monitoring of the guard-lock to EN ISO 14119

Downloads

Loading...
Choose the type of download
Mounting and wiring instructions – Ex STM 515

German, English, French, Italian, Portuguese

PDF3 MB 13.11.2025
Loading...

Other interesting products

Special version only for gas Ex zone 2 and dust Ex zone 22

ExSafety

Ex solenoid interlock

Ex STM 515 11/11 R L

Article no.: 1397480

contact us