Ex inductive sensor

Ex IS M12nb 4ABBAB N 1GD 5m

Article no.: 1298563

Standard version
contact us

Product features

Ex
  • Ex zone 0 and 20

  • Stainless steel enclosure with cable

  • M12 x 1 thread

  • Non-flush mounting

  • Long life, no mechanical wear

  • Suitable for the food processing industry

  • Insensitive to soiling

  • With LED

  • Attention: Please state required international approvals with your order!

Notes

  • 2 mounting nuts are included in delivery.

Technical data

Applied standards
EN IEC 60079-0, EN 60079-11, EN 60079-26
Enclosure
stainless steel 1.4305
Front cap
POM
Degree of protection
IP66, IP67, IP68 (EN IEC 60079-0 + IEC/EN 60529)
Connection
cable PUR blue
Cable diameter
4.1 mm
Cable cross-section
2 x 0.25 mm²
Cable length
5 m
Switching system
Namur to EN 60947-5-6
Rated switching distance sn
4 mm
Correction factors
Steel (S235JR) = 1; Stainless steel approx. 0.7; Brass approx. 0.5; Aluminium approx. 0.5; Copper approx. 0.4
Rated operating voltage range UB
8.2 VDC
Current absorption
in presence of metal ≤ 1 mA; in absence of metal ≥ 3 mA
Switching frequency
2000 Hz
Repeatability
≤ 3 %
Protection circuit
Inductive interference protection, protection against polarity reversal, short-circuit and overload proof
Ambient temperature
–25 °C … +60 °C
Ex marking
L II 1G Ex ia IIC T6 Ga,
L II 1D Ex ia IIIC T85°C Da
Approvals
IMQ 14 ATEX 001
IECEx IMQ 14.0001
f
Weight
114 g

Dimensional drawing

Further drawings

Contact diagram
Switching behaviour
Non-flush mounting
Side by side mounting

Downloads

Loading...
Choose the type of download
Mounting and wiring instructions – Ex IS M8 / M12 / M18 / M30

German, English, French, Italian, Portuguese

PDF2 MB 13.11.2025

Other interesting products

Complementary products

Ex

Ex inductive sensor

Ex IS M12nb 4ABBAB N 1GD 5m

Article no.: 1298563

Standard version
contact us