Ex position switch

Ex EM 97 TKK-11 -60°C

Article no.: 1450769

Standard version
contact us

Product features

Ex
  • Ex zone 1 and 21

  • Thermoplastic enclosure

  • Cold-resistant down to -60 °C, return of TKK spring rod actuator is restricted at temperatures < -20 °C

  • High degree of protection IP66 / IP67 / IP69

  • Mounting details to EN 50047

  • Wiring compartment

  • Actuator: Plastic spring rod TKK (insensitive to soiling)

Notes

  • 1 Ex"e" cable gland M20x1.5 included in delivery.

Technical data

Applied standards
EN 60947-5-1, EN IEC 60079-0, EN 60079-1, EN IEC 60079-7, EN 60079-31
Enclosure
thermoplastic, glass-fibre reinforced, shockproof, self-extinguishing UL 94 V-0
Cover
thermoset, glass-fibre reinforced, shockproof, self-extinguishing UL 94 V-0
Sealing
silicone
Tightening torque
cover screws: 0.4 … 0.45 Nm
Degree of protection
IP66 (EN IEC 60079-0 + IEC/EN 60529) (... -60 °C)
IP67 (EN IEC 60079-0 + IEC/EN 60529) (... -20 °C)
IP67 / IP69 (IEC/EN 60529)
IP69K (ISO 20653)
Contact material
Silver, nickel-plated
Switching system
snap action
Switching elements
1 NC/1 NO contact, type Zb
Connection
screw connection terminals
Cable cross-section
min. 0.75 mm² (AWG 18), max. 1.5 mm² (AWG 16), incl. conductor ferrules
Cable entry
M20 x 1.5; screwing depth max. 9 mm; use only Ex approved and certified cable glands with min. degree of protection IP66 and suitable for the specified ambient temperature range
Clamping range
7 … 12 mm
Utilisation category
AC-15
Rated operating current Ie
max. 2 A or 4 A X
Rated operating voltage Ue
max. 500 VAC, max. 250 VAC for unequal potential
Degree of pollution
3
Mechanical life
> 1 million operations
Impact energy
max. 7 J
Temperature class
T6
Ambient temperature
–60 °C … +55 °C max. 4 A, +60 °C max. 2 A
Short-circuit protection
2 A / 4 A gG fuse
Safety class
II
Ex marking
L II 2G Ex db eb IIC T6 Gb,
L II 2D Ex tb IIIC T80 °C Db
IECEx Ex db eb IIC T6 Gb,
Ex tb IIIC T80 °C Db
Approvals
BVS 16 ATEX E 052
IECEx BVS 16.0052
fda<
Weight
160 g

Dimensional drawing

Further drawings

Contact diagram
Switching diagram
Switching angle

Downloads

Loading...
Choose the type of download
Mounting and wiring instructions – Ex 97

German, English, French, Italian, Portuguese

PDF4 MB 12.03.2026

Variants / Options

The following variants / options are available on request:

  • 3 contacts