Product features
High degree of protection IP69
Thermoplastic enclosure with wiring compartment
Long life
Differential inputs: Induction / magnetic operating principle
Internal monitoring, high manipulation protection
Potential-free outputs
Signalling contact
Status LED
1 NO/2 NC contacts
Actuating plane: actuating from the top "T"
Notes
The actuator is not included in the delivery of the switches.
1 cable gland M20x1.5 - IP69 and 2 locking screws M20x1.5 included in delivery.
Technical data
General technical data
- Applied standards
- EN 61000-6-1, EN 61000-6-2, EN 61000-6-3, EN 61000-6-4, EN 60947-5-2, EN 60947-5-3, EN ISO 14119, EN 60204-1, EN ISO 13849-1, EN 62061, 2004/108/EG
- Enclosure
- thermoplastic, glass-fibre reinforced, shockproof, self-extinguishing UL 94 V-0
- Sensor type
- type 4 interlocking device
- Coding level
- low coding
- Tightening torque
- enclosure mounting screws: max. 2 Nm
cover screws: max. 1.5 Nm
actuator screws: max. 2 Nm
- Degree of protection
- IP69 (IEC/EN 60529)
- Rated switching distance sn
- 12 mm (10 mm with flush mounting)
- Assured switching distance »ON« sao
- 10 mm (8 mm with flush mounting)
- Assured switching distance »OFF« sar
- 25 mm
- Hysteresis
- approx. 6 mm
- Sideways tolerance
- ≤ 3 mm
- Repeatability
- ± 1 mm
- Rated operating current/voltage Ie/Ue
- 140 mA/24 VDC ± 15 %
(reverse voltage protected);
output contacts: max. 3 A/24 VAC/DC, min. 10 mA/5 VAC/DC;
signalling contact: max. 1 A/24 VAC/DC, min. 100 μA/100 mVDC
- No-load supply current I0
- ≤ 70 mA
- Short-circuit protection
- Ue: 0.25 A (slow blow);
output contacts: 4 A (gG) incoming series-connected
- Outputs
- 2 enabling paths (1 NO/1 NC)
1 signalling contact (1 NC)
- Switching voltage
- max. 30 VAC/DC
- Conditional short-circuit current
- 100 A
- Utilisation category
- AC-15; DC-13 (output contacts)
AC-12; DC-12 (signalling contact)
- Rated insulation voltage Ui
- 250 VAC
- Rated impulse withstand voltage Uimp
- 1.5 kV
- Voltage drop at Ie
- max. 0.6 V
- Overvoltage category
- III
- Switching frequency
- max. 1 Hz
- Attendance delay tv
- < 300 ms
- Risk time
- max. 165 ms
- Degree of pollution
- 3
- Ambient temperature
- 0 °C … +55 °C
- Storage and shipping temperature
- –20 °C … +70 °C
- Mechanical life
- 50 mio. operations
- Contact material
- output contacts: AgSnO self-cleaning, positive-guided; signalling contact: AgNi, gold-plated
- Contact resistance
- output contacts: 100 mΩ in new condition; signalling contact: max. 30 mΩ
- Connection
- wiring compartment with socket screw clamps 8-pole
- Cable entry
- 3 x M20 x 1.5 (for cable glands only) (press-out blanks in enclosure)
- Cable cross-section
- min. 0.14 mm² (AWG 28), max. 1.5 mm² (AWG 16)
- Weight
- 220 g
Safety-relevant data
- EN ISO 13849-1
- Performance Level PL e
- Category
- 3
- B10d (10 % load)
- 20 million
- TM
- max. 20 years
- MTTFd
- 100 years
- DC/DCavg
- 96 %
- EN 62061
- SIL CL 3
- PFHd
- ≥ 4.29 x 10-8 1/h
- hop
- 8 h/day
- dop
- 220 days/year
- tzyklus
- 20 s
- Note
- The safety-related data are based on a load of 24 V / 0.1 A / DC-1 for the enabling paths. With higher load currents for the enabling paths and other requirement rates nop, the safety-related data vary from the given data and can be provided on request.
Downloads
Loading...